IMPACT LIGHTING INC’S CLASS2 MAGNETIC DIMMABLE TRANSFORMERS
IMPACT LIGHTING INC’S Magnetic Transformers are built especially for LED systems. They provide the following benefits:
LED Magnetic Transformers have no minimum load requirements. They cause no flicker or any of the other side effects that can result from a lack of synchronization between voltage mode drivers and PWM low voltage drivers in the light fitting.
Perfect Dimming - IMPACT LIGHTING INC’S Magnetic Transformers are fully compatible with low voltage dimmers, in contrast to voltage mode drivers that balance the voltage in the system and prevent the dimmer from working.
Lower power consumption - IMPACT LIGHTING INC’S Magnetic Transformers bring about an improvement in efficiency of 15%, due to the avoidance of unnecessary double conversion in the circuitry.
No RFI issues - IMPACT LIGHTING INC’S Magnetic Transformers operate at a perfect 60Hz sinus wave and so produce no radio frequency interference whatsoever.
Compact Size - IMPACT LIGHTING INC’S Magnetic Transformers are much smaller than standard magnetic transformers, use less power - working on outputs as small as 15W - and can even be placed inside lighting fixtures.
TRANSFORMER
Input leads are 18 AWG. O utput leads are 12 AWG. Lead insulation is 105 °C. The transformer uses a class B 130 °C insulation system.
ENCLOSURE
Enclosure temperature will not exceed 70 °C @ 40 °C ambient. Wiring compartment has 2 knockouts sized for 3/4 inch screw cable connectors. The removable cover for the wiring compar tment is secured in place by a screw. The enclosure is black powder coated.
GENERAL
• Manual reset ther mal circuit breaker on the secondary side.
• Controlled with a low-voltage dimmer.
• UL listed • CSA listed • UL standard 5085-1
• NEMA 3R enclosure
CLASS 2 SINGLE OUTPUT SWITCHING POWER SUPPLY
FEATURES:
- CONSTANT CURRENT MODE POWER SUPPLY
- UNIVERSAL AC INPUT / FULL RANGE
- EPOXY ENCAPSULATED WITH IP67 LEVEL
- WITHSTAND 300VAC SURGE INPUT FOR 5 SECONDS
- PROTECTIONS: SHORT CIRCUIT / OVER CURRENT / OVER VOLTAGE
- FULLY ISOLATED PLASTIC CASE
- COOLING BY FREE AIR CONVECTION
- SMALL AND COMPACT SIZE
- UL1310 CLASS 2 POWER UNIT
- 100% FULL LOAD BURN-IN TEST
- LOW COST, HIGH RELIABILITY
- SUITABLE FOR LED LIGHTING AND MOVING SIGN APPLICATIONS
- 2 YEARS WARRANTY
ITEM#:
IL-40W-PS-C2
IL-45W-PS-C2
IL-60W-PS-C2
IL-80W-PS-C2
IL-100W-PS-C2
THE IMPACT SERIES
7.5W TO 100W LOW PROFILE DIN RAIL MOUNT POWER SUPPLIES
LOW PROFILE FOR BUILDING AUTOMATION
- 5V TO 24V OUTPUTS
- WIDE RANGE AC INPUT
- UL1310 CLASS 2(1)
- CLASS II DOUBLE INSULATION
- 25 TO +71°C OPERATION
- CONVECTION COOLED
- DIN RAIL OR CHASSIS MOUNT
FEATURE:
- LOW 2.2” PROFILE
- WIDE RANGE AC
- FULL POWER AT 61°C
BENEFITS:
- FITS INTO WALL MOUNTED CABINETS
- GLOBAL USE WITH NO INPUT SELECTOR SWITCHES
- NO DERATING NEEDED
ITEM#: IL-PS-IMPACT-SERIES
15W AC-DC (12V/1.25A) UNIVERSAL POWER SUPPLY
FEATURES:
- 12V REGULATED OUTPUT
- 1.25 AMPS
- IN LINE EMI/RFI FILTER
- UNIVERSAL AC INPUT 90-264VAC
- LOW RIPPLE NOISE
- NO MINIMUM LOAD REQUIREMENT
- 100% BURN IN TEST
- ENERGY EFFICIENT SWITCHING TECHNOLOGY
- 1.8 METER OUTPUT CORD
- FEMALE PLUG: 5.5 X 2.1MM
- UL, CUL APPROVED
ITEM#: IL-PS-12V-15W
25 WATT 12V/3.5A SINGLE OUTPUT POWER SUPPLY
FEATURES:
- COMPLIES WITH ROHS DIRECTIVE
- AC INPUT VOLTAGE RANGE: 85-264VAC
- INPUT FREQUENCY: 47-63HZ
- INRUSH CURRENT: COLD START, 20A/115V, 40A/230V
- INPUT LEAKAGE CURRENT: <0.7MA/230V
- LINE REGULATION (FULL LOAD): <± 0.5%
- OUTPUT VOLTAGE ADJ. RANGE: ± 10%
- OUTPUT OVERLOAD PROTECTION: 110-150%
- OUTPUT OVER VOLTAGE PROTECTION: 115-150%
- WITHSTAND VOLTAGE: I/P-O/P: 3.0KVAC/1MIN; I/P-F/G: 1.5KVAC/1MIN; O/P-F/G: 0.5KVAC/1MIN
- RISE TIME: 50MS@FULL LOAD (TYPICAL)
- HOLD UP TIME: 20MS@FULL LOAD (TYPICAL)
- OPERATING TEMP.& HUMIDITY: -10°C TO 50°C (14°F - 122°F), 20%-93%RH (NON- CONDENSING)
- STORAGE TEMP.& HUMIDITY: -20°C TO 85°C (-4°F - 185°F), 20%-93%RH (NON-CONDENSING)
- MTBF: 100,000 HOURS
- COOLING METHOD: CONVECTION
- UL REF. NUMBER: E258719
- EMC STANDARDS: GB9254, EN55022 CLASSB, EN55024, EN61000-3-2,3,
EN61000-4-2,3,4,5,6,8,11
ITEM# : IL-PS-12V-25W
35 WATT 12V/3.5A SINGLE OUTPUT POWER SUPPLY
FEATURES:
- COMPLIES WITH ROHS DIRECTIVE
- AC INPUT VOLTAGE RANGE: 85-264VAC
- INPUT FREQUENCY: 47-63HZ
- INRUSH CURRENT: COLD START, 20A/115V, 40A/230V
- INPUT LEAKAGE CURRENT: <0.7MA/230V
- LINE REGULATION (FULL LOAD): <± 0.5%
- OUTPUT VOLTAGE ADJ. RANGE: ± 10%
- OUTPUT OVERLOAD PROTECTION: 110-150%
- OUTPUT OVER VOLTAGE PROTECTION: 115-150%
- WITHSTAND VOLTAGE: I/P-O/P: 3.0KVAC/1MIN; I/P-F/G: 1.5KVAC/1MIN; O/P-F/G: 0.5KVAC/1MIN
- RISE TIME: 50MS@FULL LOAD (TYPICAL)
- HOLD UP TIME: 20MS@FULL LOAD (TYPICAL)
- OPERATING TEMP.& HUMIDITY: -10°C TO 50°C (14°F - 122°F), 20%-93%RH (NON- CONDENSING)
- STORAGE TEMP.& HUMIDITY: -20°C TO 85°C (-4°F - 185°F), 20%-93%RH (NON-CONDENSING)
- MTBF: 100,000 HOURS
- COOLING METHOD: CONVECTION
- UL REF. NUMBER: E258719
- EMC STANDARDS: GB9254, EN55022 CLASSB, EN55024, EN61000-3-2,3,
EN61000-4-2,3,4,5,6,8,11
ITEM# : IL-PS-12V-35W
50 WATT 12V/5A SINGLE OUTPUT POWER SUPPLY
FEATURES:
- COMPLIES WITH ROHS DIRECTIVE
- AC INPUT VOLTAGE RANGE: 85-264VAC
- INPUT FREQUENCY: 47-63HZ
- INRUSH CURRENT: COLD START, 20A/115V, 40A/230V
- INPUT LEAKAGE CURRENT: <0.7MA/230V
- LINE REGULATION (FULL LOAD): <± 0.5%
- OUTPUT VOLTAGE ADJ. RANGE: ± 10%
- OUTPUT OVERLOAD PROTECTION: 110-150%
- OUTPUT OVER VOLTAGE PROTECTION: 115-150%
- WITHSTAND VOLTAGE: I/P-O/P: 3.0KVAC/1MIN; I/P-F/G: 1.5KVAC/1MIN; O/P-F/G: 0.5KVAC/1MIN
- RISE TIME: 50MS@FULL LOAD (TYPICAL)
- HOLD UP TIME: 20MS@FULL LOAD (TYPICAL)
- OPERATING TEMP.& HUMIDITY: -10°C TO 50°C (14°F - 122°F), 20%-93%RH (NON CONDENSING)
- STORAGE TEMP.& HUMIDITY: -20°C TO 85°C (-4°F - 185°F), 20%-93%RH (NON-CONDENSING)
- MTBF: 100,000 HOURS
- UL REF. NUMBER: E258719
- EMC STANDARDS: GB9254, EN55022 CLASSB, EN55024, EN61000-3-2,3,
EN61000-4-2,3,4,5,6,8,11
- COOLING METHOD: CONVECTION
ITEM# : IL-PS-12V-50W
75 WATT 12V/5A SINGLE OUTPUT POWER SUPPLY
FEATURES:
- COMPLIES WITH ROHS DIRECTIVE
- AC INPUT VOLTAGE RANGE: 85-264VAC
- INPUT FREQUENCY: 47-63HZ
- INRUSH CURRENT: COLD START, 20A/115V, 40A/230V
- INPUT LEAKAGE CURRENT: <0.7MA/230V
- LINE REGULATION (FULL LOAD): <± 0.5%
- OUTPUT VOLTAGE ADJ. RANGE: ± 10%
- OUTPUT OVERLOAD PROTECTION: 110-150%
- OUTPUT OVER VOLTAGE PROTECTION: 115-150%
- WITHSTAND VOLTAGE: I/P-O/P: 3.0KVAC/1MIN; I/P-F/G: 1.5KVAC/1MIN; O/P-F/G: 0.5KVAC/1MIN
- RISE TIME: 50MS@FULL LOAD (TYPICAL)
- HOLD UP TIME: 20MS@FULL LOAD (TYPICAL)
- OPERATING TEMP.& HUMIDITY: -10°C TO 50°C (14°F - 122°F), 20%-93%RH (NON CONDENSING)
- STORAGE TEMP.& HUMIDITY: -20°C TO 85°C (-4°F - 185°F), 20%-93%RH (NON-CONDENSING)
- MTBF: 100,000 HOURS
- UL REF. NUMBER: E258719
- EMC STANDARDS: GB9254, EN55022 CLASSB, EN55024, EN61000-3-2,3,
EN61000-4-2,3,4,5,6,8,11
- COOLING METHOD: CONVECTION
ITEM# : IL-PS-12V-75W
100WATT 12V/8.5A SINGLE OUTPUT POWER SUPPLY
FEATURES:
- COMPLIES WITH ROHS DIRECTIVE
- AC INPUT VOLTAGE RANGE: 85-132/ 170-264VAC SELECTED BY SWITCH
- INPUT FREQUENCY: 47-63HZ
- INRUSH CURRENT: COLD START, 20A/115V, 40A/230V
- INPUT LEAKAGE CURRENT: <0.7MA/230V
- LINE REGULATION (FULL LOAD): <± 0.5%
- OUTPUT VOLTAGE ADJ. RANGE: ± 10%
- OUTPUT OVERLOAD PROTECTION: 110-130% CONSTANT CURRENT, AUTO RECOVERY
- OUTPUT OVER VOLTAGE PROTECTION: 115-150%
- WITHSTAND VOLTAGE: I/P-O/P: 3.0KVAC/1MIN; I/P-F/G: 1.5KVAC/1MIN; O/P-F/G: 0.5KVAC/1MIN
- RISE TIME: 50MS@FULL LOAD (TYPICAL)
- HOLD UP TIME: 20MS@FULL LOAD (TYPICAL)
- OPERATING TEMP.& HUMIDITY: -10°C TO 50°C (14°F - 122°F), 20%-93%RH (NON-CONDENSING)
- STORAGE TEMP.& HUMIDITY: -20°C TO 85°C (-4°F - 185°F), 20%-93%RH (NON-CONDENSING)
- MTBF: 100,000 HOURS
- UL REF. NUMBER: E258719 EMC STANDARDS: GB9254, EN55022 CLASSB, EN55024, EN61000-3-2,3,
EN61000-4-2,3,4,5,6,8,11
- COOLING METHOD: CONVECTION
ITEM#: IL-PS-12V-100W
150WATT 12V/12.5A SINGLE OUTPUT POWER SUPPLY
FEATURES:
- COMPLIES WITH ROHS DIRECTIVE
- AC INPUT VOLTAGE RANGE: 85-132/ 170-264VAC SELECTED BY SWITCH
- INPUT FREQUENCY: 47-63HZ
- INRUSH CURRENT: COLD START, 20A/115V, 40A/230V
- INPUT LEAKAGE CURRENT: <0.7MA/230V
- LINE REGULATION (FULL LOAD): <± 0.5%
- OUTPUT VOLTAGE ADJ. RANGE: ± 10%
- OUTPUT OVERLOAD PROTECTION: 110-130% CONSTANT CURRENT, AUTO RECOVERY
- OUTPUT OVER VOLTAGE PROTECTION: 115-150%
- WITHSTAND VOLTAGE: I/P-O/P: 3.0KVAC/1MIN; I/P-F/G: 1.5KVAC/1MIN; O/P-F/G: 0.5KVAC/1MIN
- RISE TIME: 50MS@FULL LOAD (TYPICAL)
- HOLD UP TIME: 20MS@FULL LOAD (TYPICAL)
- OPERATING TEMP.& HUMIDITY: -10°C TO 50°C (14°F - 122°F), 20%-93%RH (NON-CONDENSING)
- STORAGE TEMP.& HUMIDITY: -20°C TO 85°C (-4°F - 185°F), 20%-93%RH (NON-CONDENSING)
- MTBF: 100,000 HOURS
- UL REF. NUMBER: E258719
- EMC STANDARDS: GB9254, EN55022 CLASSB, EN55024, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11
- COOLING METHOD: CONVECTION
ITEM#: IL-PS-12V-150W
12 VOLT 200 WATT SINGLE OUTPUT POWER SUPPLY
- SWITCH ABLE AC INPUT RANGES (85-132VAC & 170-264VAC)
- 12VDC OUTPUT @ 16.5 AMPS
- OVERLOAD (OVER CURRENT) SHORT CIRCUIT PROTECTION
- OVER VOLTAGE PROTECTION
- INTEGRATED COOLING FAN
ITEM#: IL-PS-12V-200W
300 W, 12V/25A SINGLE OUTPUT POWER SUPPLY
FEATURES:
- 300W, 12V/25A
- HIGH RELIABILITY, LOW COST
- BUILT IN FAN SPEED CONTROL
- 100% FULL LOAD BURN-IN TEST
- PROTECTIONS: OVER CURRENT/ OVER VOLTAGE/ OVER TEMPERATURE/ SHORT CIRCUIT
- 1 YEAR WARRANTY
- DIMENSIONS: 9.64 X 4.96 X 2.6”
SPECIFICATIONS:
- AC INPUT VOLTAGE RANGE: 90-130VAC
- INPUT FREQUENCY: 47-63HZ
- INRUSH CURRENT: COLD START, 40A
- INPUT LEAKAGE CURRENT: <0.7MA
- LINE REGULATION (FULL LOAD): <±0.5%
- OUTPUT VOLTAGE ADJUST RANGE: ±10%
- OUTPUT OVER CURRENT PROTECTION: 110-130%, CURRENT LIMITING, AUTO RECOVERY
- OUTPUT OVER VOLTAGE PROTECTION: 115-150%
- WITHSTAND VOLTAGE: I/P-O/P: 1.5KVAC/1MIN: O/P-F/G: 0.5KVAC/1MIN
- RISE, HOLD UP TIME: 50MS, 20MS@FULL LOAD (TYPICAL)
- OPERATING TEMP. & HUMIDITY: -10°C/+50°C, 20%-93%RH (NON-CONDENSING)
- STORAGE TEMP & HUMIDITY: -20°C/+85°C, 20%-95%RH (NON-CONDENSING)
- COOLING METHOD: FAN
ITEM#: IL-PS-12V-300W
500W, 12V/42A SINGLE OUTPUT POWER SUPPLY
FEATURES:
- 500W, 12V/42A
- HIGH RELIABILITY, LOW COST
- BUILT IN EMI FILTER
- 100% FULL LOAD BURN-IN TEST
- PROTECTIONS: OVER CURRENT/ OVER VOLTAGE/ OVER TEMPERATURE/ SHORT CIRCUIT
- 1 YEAR WARRANTY
- DIMENSIONS: 10.0 X 6.4 X 3.48”
SPECIFICATIONS:
- AC INPUT VOLTAGE RANGE: 90-130VAC
- INPUT FREQUENCY: 47-63HZ
- INRUSH CURRENT: COLD START, 60A
- INPUT LEAKAGE CURRENT: <0.7MA
- LINE REGULATION (FULL LOAD): <±0.5%
- OUTPUT VOLTAGE ADJUST RANGE: ±10%
- OUTPUT OVER CURRENT PROTECTION: 110-130%, CURRENT LIMITING, AUTO RECOVERY
- OUTPUT OVER VOLTAGE PROTECTION: 115-150%
- WITHSTAND VOLTAGE: I/P-O/P: 1.5KVAC/1MIN :I/P-F/G: 1.5KVAC/1MIN :O/P-F/G: 0.5KVAC/1MIN
- RISE, HOLD UP TIME: 50MS, 20MS@FULL LOAD (TYPICAL
- OPERATING TEMP. & HUMIDITY: -10°C/+50°C, 20%-90%RH (NON-CONDENSING)
- STORAGE TEMP & HUMIDITY: -20°C/+85°C, 20%-95%RH (NON-CONDENSING)
- COOLING METHOD: FAN
ITEM#: IL-PS-12V-500W
6 VOLT POWER SUPPLY FOR THE PULSAR™ SYSTEM
- 6’ CARD WITH MOLDED TERMINATION
- OUTPUT: 6VDC/.2A
- TERMINATION: 3.5MM MIN PHONE PLUG
ITEM#: IL-PS-6V-200MA
AC OUTPUT TRANSFORMERS FOR IMPACT LIGHTING’S SIGNATURE™ SYSTEM
- SECONDARY: 12.6VCT, 2A
- 2.0’’(H)X2.35’’(W)X2.1’’(D)
- 2 .9 MTG HOLES
ITEM#: IL-PS-12V-AC-2A
ACCESSORIES
POWER CORD - POWER CORD TO CONNECT TO OUR POWER SUPPLY
RCA PLUG - RCA PLUG TO CONNECT TO OUR POWER SUPPLY AND TO SOME CONTROLLERS